3.1 Core Access Control Components
Overview: Core Access Control Components
An access control system is a chain of parts on a door that swings. Most of those parts are mechanical, and most real problems happen at the door, not in the software. This lesson walks the chain, shows where AI fits, and covers the reader wiring and credentials that decide how secure the door really is.
Lesson 3.1: Introduction
By the end of this lesson, you will be able to do the following.
- Name the parts of an access control system and where AI fits.
- Explain why the door itself causes most problems, and what the door contact cannot tell you.
- Describe the basics of secure reader wiring and modern credentials.
Most door problems are people and hardware, not hackers
A professional association asked 705 security managers what went wrong at their doors in the previous six months (ASIS International, 2024). The top three answers had nothing to do with the reader, the controller, or encryption.
61% tailgating
Someone followed an authorized person through the door.
50% propped doors
A door was held or wedged open.
38% badge sharing
A badge was handed to someone else.
17% technology failure
A technical failure let someone in.
The access control chain
An access control system has the same ten parts it had decades ago. What changed is that the reader wire can now be encrypted, much of the management software moved to the cloud, and video analytics were added beside the door.
Credential
The badge, card, phone, or face that identifies a person. It proves who holds the badge, not who the person is.
Reader
Reads the credential at the door and sends it to the controller.
Controller
Decides yes or no by checking the credential against a list and a schedule.
Door position switch
A magnet that reports whether the door is closed.
Request-to-exit
A motion sensor or button that lets people leave without an alarm.
Electrified lock
The strike or magnetic lock that holds or releases the door.
Power and battery
Keeps the lock and controller running, including during an outage.
Network
Connects controllers to the management software.
Head-end or cloud
The software that manages users, schedules, and reports.
Client
The screen or app people use to watch events and run reports.
Where AI fits
The yes-or-no decision at the door is still a simple lookup on the controller. No AI runs there. AI shows up in three other places.
- Cameras next to the door, for tailgating detection, counting, and loitering. These send alerts. They do not open or lock doors.
- The management software, for event search, summaries, and sorting alarms.
- A few face recognition readers, where the face itself is the credential.
When the internet drops. Most controllers, including cloud-managed ones, keep making door decisions from a list saved on site. Changes made in the cloud, such as a newly added user, may not reach the door until the connection returns and the system syncs.
The Door Contact Is the Only Sensor on the Opening
Everything else tells you what the system decided. The contact tells you what the door is doing.

The door position switch is the only sensor in the whole chain that reports the physical state of the opening rather than the state of an electrical decision. It sources your forced-door alarm and your propped-door alarm.
Here is the problem, and most technicians have seen it on the job. A magnetic contact on a hollow metal frame with a half-inch gap tolerance cannot tell a properly latched door from an unlatched door resting in the frame.
A door can be closed, the contact satisfied, the system happy, and the latch not engaged. Push it and it opens.
What this means in the field
It is part of the analytics scope
If a customer wants trustworthy door-state intelligence, the gap tolerance and the switch placement are part of the analytics scope, not a rough-in detail.
Check the latch before the software
When you are troubleshooting a door that alarms intermittently, check whether it is actually latching before you go looking at software.
The access control system records what it decided, such as granting a badge or releasing the lock. It does not record what the door actually did. Only two parts watch the physical opening. One is the magnetic door contact, and it cannot tell a latched door from an unlatched one. The other is a camera, if the customer paid for one at that door.
Wiegand and OSDP in plain words
The wire between the reader and the controller decides whether someone can tap in and copy badges. Two methods are common.
Wiegand
The older method from 1974. Data travels one way, unencrypted, and the controller cannot tell if the reader is healthy. A small device hidden behind a reader can copy badges for under 100 dollars (Coleman, 2021). It is not banned, but it is easy to attack.
OSDP
The newer Open Supervised Device Protocol. Data travels both ways, the controller knows if a reader goes offline, runs can be much longer, and Secure Channel adds AES-128 encryption. It is only secure if you turn the encryption on and set it up correctly.
Go deeper (optional)OSDP Secure Channel field wiring and setup+
Wiegand, OSDP, and Encryption on the Reader Wire
The reader-to-controller wire is now capable of real cryptography. Here is what that gives you, and what it takes in the field to get it.
Status checked October 2026

Wiegand was invented in 1974 and became the de facto standard by 1996. It is one-directional, so the controller cannot verify the reader's health, tamper state, or identity. The data travels in the clear as simple pulses. And it is easy to intercept. The industry association's own article prices the attack at under 100 dollars (Coleman, 2021).
OSDP, the Open Supervised Device Protocol, replaces it. It is two-way, supervised, multi-drop, and capable of AES-128 encryption on the reader-to-controller link.
| Wiegand | OSDP | |
|---|---|---|
| Maximum distance | About 500 ft | About 4,000 ft |
| Direction | One way | Two way |
| Multiple devices on one run | No | Yes |
| Supervision (does the controller know the reader is alive?) | No | Yes |
| Encryption | None | AES-128 via Secure Channel |
Versions and standards
The current version. As of September 2026, the current released version is v2.2.2, dated October 31, 2024. Do not write a higher number into a specification. Nothing above 2.2.2 has been released. The version before it, 2.2.1, was withdrawn because it contained errors.
International standard versus OSDP version. OSDP was adopted as an international standard, IEC 60839-11-5, which is still at its 2020 first edition, while the industry association's own specification has advanced two revisions past that. So a specification citing the international standard and one citing OSDP v2.2.2 are not asking for the same thing.
Wiegand is not banned. No U.S. authority has banned it. The controlling federal procurement guide for access control, dated December 2025, still lists Wiegand among acceptable reader communication methods with no stated preference (GSA, 2025). "Deprecated by industry consensus" and "prohibited" are different claims, and mixing them up in front of a customer costs you credibility.
OSDP Secure Channel field requirements
This is the part most training skips. Open each panel for the field detail.
Cable
The guidance says "cabling rated for 2-wire RS-485," and that phrasing is a documented field trap. RS-485 needs a common ground reference, so the real requirement is three conductors plus shield. Characteristic impedance is 120 ohms. Terminate at the reader end only, not the panel. Ground the shield at the panel end only.
Distance versus baud rate
On 24 AWG twisted shielded pair. Default baud is 9,600 and the default reader address is 1.
| Baud rate | Maximum distance |
|---|---|
| 9,600 | 4,000 ft |
| 19,200 | 3,200 ft |
| 38,400 | 3,000 ft |
| 57,600 | 2,300 ft |
Power is a separate calculation, and it fails first
Maximum reader power run by reader draw and wire gauge.
| Reader draw | Wire gauge | Maximum run |
|---|---|---|
| 300 mA | 16 AWG | 459 ft |
| 300 mA | 18 AWG | 289 ft |
| 300 mA | 20 AWG | 198 ft |
| 400 mA | 18 AWG | 216 ft |
Sequencing
Sequencing is a documented failure cause. Put the reader in install mode before enabling Secure Channel, or the link fails. If a secure link is unstable, lower the baud rate, power cycle, and resync the controller. Re-link the reader if you move it to a different port.
Track the Secure Channel keys
The commissioning checklist requires cataloging each device's address, configuration, serial number, firmware version, cabling, Secure Channel keys, and physical location. Bench test the whole thing before it goes on the wall.
Go deeper (optional)How Wiegand is defeated, and OSDP weak points+
How Wiegand Is Defeated, and OSDP Weak Points
Three ways a legacy installation fails, then the five OSDP weaknesses that are usually left out of training entirely.
The credential format itself
The common 26-bit format has 255 possible facility codes and 65,535 card numbers per facility code, about 16.7 million combinations in total. The manufacturer designates it an open format, publishes the specification, and states that it does not restrict duplication of card numbers.
So a 26-bit credential population is not merely unencrypted. It is not unique. Two different buildings can legitimately hold identical facility-code and card-number pairs, bought through ordinary channels. No reader or panel change fixes that. It takes a format migration.
The wire
The common attack tool is a small implant that goes in behind the reader, logs credentials as authorized people use the door, and replays them. It can also run the door by itself, driving the strike or maglock directly and bypassing the panel entirely. It is a commodity product sold by multiple vendors, not a research prototype.
Range
Published security research built a portable long-range reader around a standard long-range prox reader plus that implant, achieving a read at three or more feet from a badge in someone's pocket. Vulnerable cards include 125 kHz prox and higher-frequency cards still running default encryption keys (Watson, 2018).
On the job, remember this. The strength of a credential is capped by the weakest link downstream of it. A modern encrypted card read by a multi-protocol reader that outputs the result over Wiegand is fully defeated. You did not buy security. You bought an expensive card.
Five OSDP weaknesses found in 2023
In August 2023, published security research demonstrated five separate weaknesses in OSDP as deployed, with a released tool, using nothing more than a laptop and USB-to-RS-485 adapters (Petro, 2023).
Encryption is optional in the protocol
The researchers tested a controller that claimed OSDP compatibility and had no encryption capability at all.
Downgrade attack
During reader startup, the capability announcement cannot itself be encrypted. An interposed device edits the announcement to claim the reader does not support encryption, and the controller proceeds in the clear.
Install mode left on
In install mode a reader can request the key. Getting out of install mode is a manual administrative step, and in the researchers' words, many never do it.
Weak and hardcoded keys
Publicly circulating sample code contains hardcoded keys, and common patterns are a single byte repeated or a simple ascending or descending sequence. The researchers characterized the practical search space as roughly 768 testable keys.
Key capture during reader replacement
There is no secure key exchange mechanism. Disable a reader, put a listener on the RS-485 run, and capture the key when the replacement gets keyed on site.
The researchers' advice was simple. Do not trust something just because it is encrypted.
Their recommended fixes are all things a technician controls. Buy hardware that is actually verified rather than merely claiming support. Configure the controller to refuse unencrypted reader connections. Turn install mode off when you leave. Investigate tamper alarms immediately. Treat an unexpected reader-offline event as a possible precursor to a key-capture attempt, not just a nuisance.
Cards and phones, from weakest to strongest
A credential is only as strong as its technology and the wiring behind it. Here is the short version. The Go deeper cards below have the details.
125 kHz prox cards
No encryption. They send a fixed number and can be copied from about three feet away. Still in use at about one organization in five.
Older smart cards
Some popular older smart card chips have been broken. "Smart card" means little without the exact chip model.
Current encrypted smart cards
The best ones publish their encryption type and third-party test results. Ask for that paperwork.
Phone badges
Most are a tap at the reader using NFC, like paying with a phone. A new standard called Aliro, released in 2026, aims to make phone badges work across brands.
Go deeper (optional)Credential types and how secure they are+
Credentials in Use in 2026
What is actually in use, how fast legacy cards are leaving, and what each card family really delivers.

The same vendor-neutral survey reported these credential technologies in use (ASIS International, 2024).
Legacy cards are declining slowly
From 2019 to 2023, 125 kHz prox went from 51 percent to 22 percent, and magstripe went from 26 percent to 7 percent. Legacy prox lost more than half its share in four years and is still in roughly one organization in five. It is dying, not dead, which means you will keep meeting it.
Card types and how secure they are
The details decide whether a card migration was worth paying for. Open each card type.
125 kHz prox
No cryptography at all. The card transmits a fixed number. Defeated at three-plus feet by commodity gear.
MIFARE Classic
Comprehensively and repeatedly broken across sixteen years of peer-reviewed work. And in August 2024 a researcher published a hardware backdoor in a widely deployed "MIFARE compatible" chip that permits compromise of all user-defined keys, even fully diversified ones, in a few minutes of card access. A common backdoor key was found across several manufacturers' older parts, not just one (Teuwen, 2024).
So "MIFARE" on a purchase order in 2026 means nothing without the exact chip part number.
MIFARE DESFire
The original generation was broken by side-channel attack in 2011, and the researchers stated plainly that the next AES-based generation was not affected and included countermeasures. That is an unusually clean example of a real break being closed by the following generation.
The current generation publishes a full data sheet. It lists AES-128, a named third-party evaluation level, the exact standards it conforms to, 25-year data retention, and a built-in proximity check for relay-attack protection.
Older high-frequency proprietary cards
Broken twice over. One researcher extracted the keys from a reader through an exposed programming connector, which meant that breaking one reader could open doors anywhere that system was used. Separate peer-reviewed work dismantled both the standard and the high-security variants, the latter in under five seconds on an ordinary laptop.
The current premium proprietary credential
The manufacturer's published pages state that it uses modern cryptography and mutual authentication. They name no algorithm, no conformance statement, no evaluation level, and no public specification. Technical questions route to sales.
Read that last panel as a contrast, not a verdict. One manufacturer publishes the algorithm, the evaluation level, and the exact standards clauses. Another publishes marketing language. The second product may well be perfectly sound. The point is that a buyer cannot verify it from published material, and that is a procurement fact you are entitled to put in a comparison.
Go deeper (optional)Phone badges, Aliro, and Bluetooth risks+
Phone Badges Are NFC Taps
Phone badges are often misstated in the field. Here are the facts.
Status checked October 2026

The employee badges built into the major phone platforms are NFC credentials. Neither is Bluetooth. Neither is ultra-wideband.
Which means the user experience is a tap. Express Mode removes the step of unlocking the phone, so it feels effortless, but it is still a tap against the reader, not a hands-free walk-up.
Phone platform A badge
- A recent phone or smartwatch on that platform
- An employer-provided app
- The badge syncs automatically to a paired watch
- Express Mode allows a tap without unlocking
Phone platform B badge
- A recent phone on that platform, with NFC turned on
- Readers capable of accepting the credential over the provider's supported protocol
- Still a tap, not a walk-up
Hands-free comes from somewhere else
Hands-free behavior in 2026 comes from vendor-native Bluetooth apps, and that is where the security question lives.
Aliro 1.0, released February 26, 2026, changes this layer. It is a vendor-neutral device-to-reader credential standard using asymmetric cryptography, with NFC for tap, Bluetooth LE for user-initiated unlock at range, and Bluetooth LE plus UWB for hands-free. A certification program exists and is operational. The major phone makers and the major lock and reader manufacturers are participants.
No certified products at release
Those participating companies were expected to be the first to certify.
Aliro does not replace OSDP
Its scope is user device to reader only. It says nothing about reader to controller. They are adjacent links, and a building needs both.
UWB is specified, not available
As of September 2026, no UWB-based enterprise employee badge product has been confirmed as shipping. Treat UWB as specified and imminent, not as available, and say so plainly rather than letting a customer assume otherwise.
In May 2022 published research demonstrated a Bluetooth Low Energy link-layer relay attack that works through BLE encryption, because the relay operates below the cryptography. The tool added as little as 8 milliseconds of round-trip latency, and the attack still succeeded with 80 milliseconds artificially added, which means an internet-relayed version is feasible. The researchers said the exposure reached millions of cars, mobile devices, and locking systems, including smart locks (NCC Group, 2022).
Their recommended structural fix is time-of-flight ranging, such as ultra-wideband. Latency limits in software are a partial defense. Measuring the actual distance is the real one. That is exactly why the current DESFire generation implements a proximity check in the card, and why the new credential standard defines a UWB ranging role.
Where the AI Actually Runs
The short answer is that essentially no AI runs in the access decision path.

The access decision in 2026 is still a database lookup against a credential number, a schedule, and an access level, executed on a controller. What AI does exist sits in three places.
In the video layer next to the door
Tailgating detection, people counting, loitering, line crossing. These feed alerts, not door decisions.
At the head-end and client
Event search, incident summarization, alarm triage, plain-language reporting.
Inside a small number of biometric readers
Where the face recognition is itself the credential.
AI adoption figures depend on who ran the survey
The vendor-neutral association, fielded 2023, found 10 percent using AI or machine learning to analyze access logs. One vendor's survey, fielded 2025, found 21 percent average AI deployment in physical security. Another vendor's survey, fielded 2026, found 41 percent actively using AI.
Some of that spread is real growth. The fieldwork dates are three years apart. But notice that the figures also rise monotonically with the sponsor's commercial interest in the answer being high, and that the questions were not the same question. One asked specifically about AI analysis of access logs. Another asked about AI features on a platform where most AI features are video.
Tailgate detection, the best-documented AI access feature
Its documentation shows that the install constraints decide how well it works.
- The camera must be inside the door, opposite the reader, above the frame.
- Mounted at 10 to 55 degrees off perpendicular.
- The door occupies at least 80 percent of the frame, within a maximum distance that varies by camera model.
- Events populate within about three minutes.
- It is alert and monitoring only. There is no automatic door denial.
- No accuracy rate and no false-positive rate are published.
Face recognition
A government program has evaluated 1,462 algorithms from 447 developers and publishes measured error rates at stated operating thresholds, for free (NIST, 2026). A technician can look that up.
Access-control AI features
You cannot look up a single one that way. Not tailgating detection, not anomaly detection on logs, not AI alarm verification, not incident summarization. No vendor publishes an accuracy figure for any of them.
That absence is not a gap in one product page. It is the current state of the field. Know it before you quote any of these features.
Go deeper (optional)Each part of the chain, what changed, and what still fails+
Each Component, What Changed, and What Still Fails
Ten links, the 2026 change at each one, and the failure that defeats the intelligent features layered on top.
| Link | What 2026 changed | The failure that defeats intelligent features |
|---|---|---|
| Credential | Phone wallet badges are now supported directly by the major phone makers. A new vendor-neutral standard, Aliro 1.0, was released in February 2026. | A credential authenticates a token, never a person. Badge sharing was reported by 38 percent of respondents. No amount of cryptography on the card touches that. And legacy cards stay in service. 22 percent still had 125 kHz prox in use. |
| Reader | Readers are multi-protocol and configured by phone app instead of DIP switches. A few readers now contain the AI themselves. Face recognition readers appear on the standards-verified manufacturer list. | Multi-protocol readers ship with legacy protocols enabled for backward compatibility. A reader that will read both an old prox card and a modern encrypted card hands an attacker the weaker of the two. Security posture is now a commissioning decision, and it is usually left at default. |
| Controller | Cellular backup is now a shipping feature. Cloud-managed controllers dominate new small and mid-size work. | Line security to the host is optional and usually off. One mainstream enterprise controller is listed at the lowest of four line-security levels, with host encryption described as an available option. Separately, controllers are remotely exploitable. A 2024 federal advisory documented missing authentication on a major door controller line, scored 9.1, affecting all versions with no patch. The remedy was replacing the hardware. |
| Door position switch | Electrically, nothing. What changed is that this switch is now the input every "door anomaly" dashboard mines. | See the next section. This is the highest-leverage thing in the lesson. |
| Request-to-exit | Nothing. | Silent failure, in both directions. Failed open gives you nuisance forced-door alarms, which get shunted. Failed closed on a maglock with hardware release is a life-safety failure nobody discovers until somebody tries to leave. |
| Electrified lock | Nothing mechanical. | Alignment and preload. HVAC pressure differentials create resistance the strike cannot overcome, and the release failure gets misdiagnosed as a defective strike. |
| Power and battery | Networked power supplies are now recommended practice so they can be managed remotely. | Voltage drop and an unmonitored battery. There is a documented case of a backup battery consuming power rather than supplying it, pulling down voltage at the far door. |
| Network | Cellular backup at the controller. Federal cloud systems must ride authorized services with domestic data residency. | The network is now the AI dependency. Edge-resident access decisions survive an outage. Cloud-resident intelligence does not. |
| Head-end or cloud | This is where essentially all the shipping AI lives. | Data quality. Anomaly detection running over an event stream full of shunted alarms, shared badges, and ambiguous door states will faithfully learn the dysfunction and call it normal. |
| Client | Natural-language search and AI-written incident summaries are shipping. | Summary confidence exceeding evidence quality. No vendor publishes an accuracy figure for any of it. |
Go deeper (optional)Panel, edge, and cloud controllers, and working offline+
Panel, Edge, and Cloud Controllers, and Offline Operation
Three controller layouts, the lock power limit, two surveys that disagree, and the federal rule for working offline.
Three architectures
Classic panel
A multi-door panel in a closet, with a homerun cable to each door.
Edge controller
A controller at the opening, powered and networked over one cable.
Cloud-managed
The local controller still makes the access decision, while policy, identity, event archive, and reporting live in a vendor's cloud.
Lock power limits edge controllers
Power over Ethernet gives you 15.4 watts at the port under the original standard, 30 under the next, and 60 or 90 under the four-pair standards. Against that, a long-standing industry assessment was that 40 to 50 percent or more of locks on the market are unsuitable for edge controllers. Light-duty strikes and low-holding-force magnets are generally fine, while heavier locks and electrified panic hardware are almost guaranteed to draw too much. And the controller's own consumption competes with the lock for the same budget.
Cloud adoption surveys disagree by a factor of five
Vendor survey A
- 7,368 respondents
- Fielded August to September 2025
- 43 percent fully on premises
Vendor survey B
- 2,741 respondents
- Fielded March to April 2026
- 8 percent entirely on premises
Both disclose methodology. Both cannot be right. The gap is explainable. The surveys were six months apart, with different population floors, one sample heavily weighted to channel partners and the other to IT and security leaders, and different question wording.
This pair shows why a percentage without a sponsor, a denominator, a date, and the actual question wording is not evidence. Do not average them. Do not pick one.
The most defensible number in this area is not a survey at all. It is a count of a closed, published, government-maintained list of approved federal access control solutions. Roughly 15 percent of the approved solutions are cloud-topology. That is not a sample. That is the whole list.
Cached authorization is a federal architecture
Customers ask whether the doors work when the internet drops. The right answer starts with the fact that cached authorization is not a cloud-vendor workaround. It is a federally documented architecture. The governing NIST publication for credentials at doors explicitly anticipates that online validation will not always be practical, and sanctions a caching proxy refreshed at least once every 24 hours.
The best-documented vendor offline specification caches up to 1,000 access rights and 250 groups, covers up to 36 hours of outage, and syncs once daily at midnight. These limits matter most in the field.
- A newly added user will not work offline until after their first sync cycle.
- Only frequently used credentials are cached, so inactive users may be excluded.
- Phone-based offline access requires the phone itself to have been online to fetch a certificate first.
- The phone offline cache does not work with third-party readers.
Go deeper (optional)Power and door hardware details+
Power and Door Hardware Still Cause Most Failures
The survey found that workmanship beats cryptography as a cause of failure by two to one. Here is what that looks like at the door.

Voltage and current limits
12 VDC plus or minus 10 percent, or 24 VDC plus or minus 10 percent, with a maximum 5 percent voltage drop. A worked example from a manufacturer's guide totals 486 mA for one door. Notice how fast that adds up against the wire distances in the Secure Channel panels above.
Common power and door failures
These come from practitioner documentation.
- Wall-wart supplies that get unplugged, or plugged into a receptacle controlled by a light switch.
- Backup batteries that have gone bad and are drawing power instead of supplying it.
- Wire gauge chosen without calculating voltage drop, so the farthest door browns out.
- Request-to-exit switches as a primary suspect in maglock misbehavior. Test them as part of troubleshooting, not as an afterthought.
- The recommendation to use slave relays so inductive lock loads are isolated from controller outputs.
Electric strikes
Alignment drifts over time, and preload from building air-pressure differentials creates resistance the strike cannot overcome. Both present as "the strike is bad." Also, field-cutting a frame to fit a strike often violates fire code. You cannot put a strike wherever you want.
Mechanical benchmarks exist
A Grade 1 mortise lock must pass one million cycles of opening and closing with a ten-pound load applied. That is a real, published, testable number, which puts it ahead of most of the AI features in this module.
Access control units are listed under a standard with four performance categories (destructive attack, line security, endurance, and standby power), each rated Level I through Level IV.
Two things a technician should take from that. First, a flagship enterprise controller's own published listing shows Endurance Level IV but Line Security Level I. That is the lowest of four on the panel-to-host link, consistent with encryption being an option rather than a default. "UL listed" does not mean "listed at a high level in the category you care about."
Second, that same document, revised in September 2024, cites an edition of the standard that had already been superseded twice. Listing paperwork lags the standard by years. Read the edition, not just the number.
What to tell the customer
An office manager wants to add an AI tailgating feature at the main entrance.
Key Terms
Click any term to reveal its definition.
Door position switch (DPS)+
The contact reporting whether the door is closed. The only sensor in the chain observing the physical opening rather than an electrical decision. Cannot distinguish a latched door from an unlatched door resting in the frame.
Request-to-exit (REX)+
The device that suppresses the forced-door alarm on legitimate egress and, in maglock installations with hardware release, directly interrupts lock power as a code-required release path.
OSDP+
Open Supervised Device Protocol. The two-way, supervised, multi-drop replacement for Wiegand on the reader-to-controller link. Current released version v2.2.2, October 31, 2024.
Secure Channel+
OSDP's AES-128 encrypted session between controller and reader, established with a Secure Channel Base Key. Optional in the protocol, so it must be verified as actually negotiated, not assumed.
Install mode+
A reader state used during commissioning in which the reader can request the Secure Channel key. Leaving it on is a documented vulnerability. Turning it off is a manual step.
Downgrade attack+
An interposed device edits a reader's unencrypted capability announcement to claim no encryption support, so the controller proceeds in the clear.
26-bit format+
The common legacy Wiegand credential format, with 255 facility codes and 65,535 card numbers each. Published as an open format with no restriction on duplicate card numbers, so credentials are not unique.
Relay attack+
Forwarding an authentication exchange between a distant credential and a reader in real time. A documented Bluetooth link-layer version works through encryption because it operates below the cryptography.
Proximity check / time-of-flight ranging+
Measuring the actual physical distance to a credential rather than limiting response latency. The structural defense against relay attacks. Implemented in current smart cards and specified for ultra-wideband.
Aliro+
A vendor-neutral device-to-reader credential standard released February 2026, defining NFC, Bluetooth LE, and Bluetooth LE plus UWB roles. Covers credential to reader only, not reader to controller.
ACaaS+
Access Control as a Service. The access decision stays on a local controller while policy, identity, event archive, and reporting run in a vendor-operated cloud.
Caching status proxy+
A federally sanctioned architecture in which credential validation status is cached locally and refreshed at least every 24 hours, so doors function during a loss of connectivity.
Preload+
Force on a latch from building air-pressure differentials or door misalignment that an electric strike may be unable to overcome. Presents as a defective strike.
OSDP Verified+
A designation meaning a device was actually tested against the specification. Distinct from the unregulated marketing claims "supports OSDP" and "OSDP compliant."
References
+
- Apple. (n.d.). Use your employee badge in Apple Wallet. https://support.apple.com/guide/iphone/use-your-employee-badge-iphc8f0d0be5/ios
- ASIS International. (2024). Access control research project 2023-24. https://www.asisonline.org/publications--resources/research/
- BHMA. (2022). ANSI/BHMA A156.13-2022: Mortise locks and latches. Builders Hardware Manufacturers Association. https://buildershardware.com/standards/
- Coleman, D. (2021, November 9). Why the security industry is moving away from Wiegand. Security Industry Association. https://www.securityindustry.org/2021/11/09/why-the-security-industry-is-moving-away-from-wiegand/
- Connectivity Standards Alliance. (2026, February 26). Aliro 1.0 released: A unified standard for mobile access control [Press release]. https://csa-iot.org/newsroom/
- de Koning Gans, G., Hoepman, J.-H., & Garcia, F. D. (2008). A practical attack on the MIFARE Classic. In Smart Card Research and Advanced Applications (CARDIS 2008), 267-282. https://doi.org/10.1007/978-3-540-85893-5_20
- Garcia, F. D., de Koning Gans, G., Verdult, R., & Meriac, M. (2012). Dismantling iClass and iClass Elite. In Computer Security: ESORICS 2012, 697-715. https://doi.org/10.1007/978-3-642-33167-1_40
- General Services Administration. (2025, December). Physical access control systems customer ordering guide. https://www.gsa.gov/technology/it-contract-vehicles-and-purchasing-programs/information-technology-category/it-security/physical-access-control-systems-pacs
- HID Global. (n.d.). Understanding card data formats. https://www.hidglobal.com/documents/understanding-card-data-formats-wp-en
- International Electrotechnical Commission. (2020). Alarm and electronic security systems: Part 11-5: Electronic access control systems: Open supervised device protocol (OSDP) (IEC 60839-11-5:2020). https://webstore.iec.ch/publication/32100
- National Institute of Standards and Technology. (2018). Guidelines for the use of PIV credentials in facility access (NIST Special Publication 800-116 Rev. 1). https://doi.org/10.6028/NIST.SP.800-116r1
- National Institute of Standards and Technology. (2026). Face Recognition Technology Evaluation (FRTE) 1:1 verification. https://pages.nist.gov/frvt/html/frvt11.html
- NCC Group. (2022, May 15). Technical advisory: BLE link layer relay attack. https://www.nccgroup.com/us/research-blog/technical-advisory-ble-proximity-authentication-vulnerable-to-relay-attacks/
- ONVIF. (2021, July 14). ONVIF releases Profile D for access control peripherals [Press release]. https://www.onvif.org/profiles/profile-d/
- Oswald, D., & Paar, C. (2011). Breaking Mifare DESFire MF3ICD40: Power analysis and templates in the real world. In Cryptographic Hardware and Embedded Systems: CHES 2011, 207-222. https://doi.org/10.1007/978-3-642-23951-9_14
- Petro, D. (2023, August 9). Bad things come in threes: Attacking OSDP. Bishop Fox. https://bishopfox.com/blog/attacking-osdp
- Security Industry Association. (2024, October 31). OSDP v2.2.2 released. https://www.securityindustry.org/industry-standards/open-supervised-device-protocol/
- Security Industry Association. (2026). OSDP Verified products. https://www.securityindustry.org/industry-standards/open-supervised-device-protocol/osdp-verified/
- Teuwen, P. (2024). MIFARE Classic: Exposing the static encrypted nonce variant... and a hardware backdoor (IACR ePrint 2024/1275). https://eprint.iacr.org/2024/1275
- Watson, R. (2018, January 26). Long range RFID badge reading with an ESPKey. NetSPI. https://www.netspi.com/blog/technical-blog/physical-security/
Explore & Complete
Complete the Knowledge Check below. Navigate through each slide and answer every question. You have unlimited attempts to answer each question correctly.
Next Steps
After you have earned a perfect score on the Explore & Complete activity, click the Mark Complete button to complete this lesson. You can then move to the next lesson.